2.4.2 EVAPORATOR1. Remove the cabinet.2. Discharge the refrigerant by using a refrigerantrecovery system.3. Remove the upper air guide . (Refer to Se
—10—Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment, pinch-off tool capableof making a vapor proof seal, leak dete
—11—2.4.4 ELECTRICAL DATAUSE OF EXTENSION CORDSBecause of potential safety hazards, we strongly discourage the use of an extension cord. However, if y
—12—3.2 PIPING SYSTEMFollowing is a brief description of the important components and their function in what is called the refrigerationsystem. Refere
—13—3.3 TROUBLESHOOTING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused by an electr
—14—Fails to Start Improper thermostat settingLoose terminal connectionImproper wiring Check voltage power source. Drop of power voltage. Capacitor ch
COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to electronic con
—16—&203/$,17 &$86( 5(0('<)DQPRWRUQRLVH )DQEODGH ,IFUDFNHGRXWRIEDODQFHRUSDUWLDOO\PLVVLQJUHSODFHLW%ORZHU wheel ,
—17—COMPLAINT CAUSE REMEDY Compressor cycles on Fan motor If not running, determine the cause. Replace if overload. required. Condenser air flow R
—18—4. CIRCUIT DIAGRAM(SMPS) 250V/T2A(250V/T3.15A)MEZ62420702WH(BL)LOCATIONPART NO Q'TYNO.CP05N10A PER SET1 POWER CORD ASSY67300020 12FAN MOTOR
—2—CONTENTS1. PREFACE ...
²19²(;3/2'('9,(:352390-2::$0
—20—LocNo DESCRIPTION CP05N10A130410 Base Assembly,Weld67302931130910 Cabinet67303719135312 Grille Assembly,Front67306008135303 Grille,Inlet6730610714
Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540• (210) 357-4400 • FAX (210) 357-4490FRIEDRICH AIR CONDITIONING CO.Vis
1. PREFACEThis service manual provides various service information, including the mechanical and electrical parts, etc. This room air conditioner was
—3—1.3 LOCATIONS OF CONTROLS MONEY SAVER2The fan stops when the compressor stops cooling.• Approximately every 3 minutes the fan will turn on and samp
—4—2. DISASSEMBLY INSTRUCTIONS2.1 MECHANICAL PARTS2.1.1 FRONT GRILLE 1. Pull the inlet grille forward.2. Remove the screw securing the Front Grille. (
—5—2.2 AIR HANDLING PARTS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 2.1.1)3.
—6—2.2.3 MOTOR1. Disconnect the unit from the power source.2. Remove the front grille. (Refer to Section 2.1.1)3. Remove the cabinet. (Refer to Sectio
—7—2.3.2 COMPRESSOR 1. Remove the front grille and cabinet. (Refer to Section 2.1) 2. Discharge the refrigerant by using a refrigerantrecovery system.
—8—2.3.6 POWER CORD1. Disconnect the unit from source of power.2. Remove the front grille. (Refer to Section 2.1.1)3. Remove the cabinet. (Refer to Se