Friedrich UE08 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Climatiseurs à système divisé Friedrich UE08. Friedrich UE08 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 23
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
UE08/UE10/UE12 (04/07)
230 Volts UE10:Staring with serial number LGDK00001
UE12:Staring with serial number LGDK00001
Thru-the-Wall Series
Thru-the-Wall Series
Service and Parts
Ma
nual
115 Volts UE08:
Staring with serial number LGCK00001
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - Thru-the-Wall Series

UE08/UE10/UE12 (04/07)230 Volts UE10:Staring with serial number LGDK00001 UE12:Staring with serial number LGDK00001 Thru-the-Wall SeriesThru-the-Wa

Page 2 - CONTENTS

—10—— Replacement of the refrigeration cycle.1. When replacing the refrigeration cycle, be sure todischarge the refrigerant system using a FreonTMreco

Page 3 - 1.3 SPECIFICATIONS

—11—Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off toolcapable of making a vapor-proof seal, Leak dete

Page 4 - 1.5 CONTROL LOCATIONS

—12—3. TROUBLESHOOTING GUIDE3.1 OUTSIDE DIMENSIONS 19-21/32"(499mm)24-21/32"(626mm)14-13/32"(366mm)CONDENSER COILSEVAPORATOR COILSFAN

Page 5 - 2. DISASSEMBLY INSTRUCTIONS

—13—3.3 TROUBLESHOOTING GUIDEIn general, possible trouble is classified in two causes.The one is called Starting Failure which is caused from an elect

Page 6 - 2.2 AIR HANDLING PARTS

—14—Fails to StartCheck circuit breakerand fuse.Gas leakage at feeler bulbof thermostatCheck control switch.Only fan fails to start.Improper wiring.De

Page 7 - 2.3 ELECTRICAL PARTS

—15——15—COMPLAINT CAUSE REMEDYCheck voltage at outlet. Correct if none.Check voltage to rotary switch. If none, checkpower supply cord. Replace cord i

Page 8 - 2.3.6 ROTARY SWITCH

—16—NAME PLATE RATING MINIMUM MAXIMUM115V 103.5V 126.5V208/230V 187V 253VCOMPLAINT CAUSE REMEDYCheck voltage. See the limits at the bottom of thispage

Page 9 - 2.4 REFRIGERATION CYCLE

—17—COMPLAINT CAUSEREMEDYCheck the voltage. See the limits on the preced-ing page. If not within limits, call an electrician.Check overload, if extern

Page 10

—18—4. SCHEMATIC DIAGRAM4.1 CIRCUIT DIAGRAM• MODEL : UE08A13B/UE10A33B/UE12A33B6411A20056L 6411A20056Q2H00598F4681A20044H 4681A20041C 4681A20041

Page 11

—19—5. EXPLODED VIEW• MODEL: UE08A13B/UE10A33B/UE12A33B753011W48602559010346811349600567502349001130410W48602137215149410W0CZZ264110130900135312147581

Page 12 - 3. TROUBLESHOOTING GUIDE

—2—1. PREFACE1.1 SAFETY PRECAUTIONS ...21.2 INSULATION RESISTANCE TEST...21.3 SPECIFICATIONS ...

Page 13 - 3.3 TROUBLESHOOTING GUIDE

—20—6. REPLACEMENT PARTS LISTR: Service PartsN: Non Service partsLocNo FRD P/NO DESCRIPTION REMARKW0CZZ 67300725 CAPACITOR, DRAWING R266003 67300502 S

Page 14

LocNo FRD P/NO DESCRIPTION REMARK266003 67300502 SWITCH, ROTARY R269310 67300404 THERMOSTAT ASSEMBLY R130410 67302919 BASE ASSEMBLY, SINGLE R130900 67

Page 15

LocNo FRD P/NO DESCRIPTION REMARK130410 67302921 BASE ASSEMBLY, SINGLE R130900 67303705 CABINET R135312 67306005 GRILLE ASSEMBLY, FRONT(SINGLE) R13531

Page 16

UE08/UE10/UE12 (06/07)Printed in ChinaPost Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 35

Page 17

—3—1.3 SPECIFICATIONS1.3.1 FOR UE08A13B/UE10A33B/UE12A33BREMARKPOWER SUPPLYCAPACITY (Btu/h)INPUT (W)RUNNING CURRENT(A)E.E.R. (Btu/W.h)CAPACITY (Btu/h)

Page 18 - 4. SCHEMATIC DIAGRAM

1.4 FEATURES• Designed for cooling only.• Powerful and quiet cooling.• Top-down chassis for the simple installation and service.1.5 CONTROL LOCATIONS•

Page 19 - 5. EXPLODED VIEW

—5—2.1 MECHANICAL PARTS2.1.1 FRONT GRILLE1. Open the inlet grille downward.2. Remove the screw which fastens the front grille.3. Pull the front grille

Page 20 - 6. REPLACEMENT PARTS LIST

Figure 7—6—2.2 AIR HANDLING PARTS2.2.1 ORIFICE, HEATER ASSY ANDTURBO FAN1. Remove the front grille. (Refer to section 2.1.1)2. Remove the cabinet. (Re

Page 21

—7—2.2.3 SHROUD1. Remove the fan. (Refer to section 2.2.2)2. Remove the screw which fastens the shroud.3. Remove the shroud. (See Fig. 9)4. Re-install

Page 22

—8—2.3.4 POWER CORD1. Remove the control box. (Refer to section 2.1.3)2. Unfold the control box. (Refer to section 2.3.3)3. Disconnect the grounding s

Page 23 - P/NO.:3828A20040L

—9—2.4 REFRIGERATION CYCLE2.4.1 CONDENSER1. Remove the cabinet. (Refer to section 2.1.2)2. Remove the brace and the shroud cover.(Refer to section 2.2

Commentaires sur ces manuels

Pas de commentaire